ReignPower LP1300D-24M Series
SKU : LP1300D-24M Series
Price |
4,000.00 THB |
Quantity to buy | |
Total | 4,000.00 THB |
Do not have enough stock
Out of stock
Switching Power Supply
AC to DC Switching Power Supply
LP1300D Series
Features
Green Power
- Din Rail / Screw Mounting Dual Purpose
- Easy mounting (one-step installation)
- Comply with high Efficiency Power 80Plus Criterion
- "Output Voltage Monitor" Display
- Convection cooled high reliability
- 100% burn-in test
- 1 years warranty
- Output modify range: 3V~200VDC
DIMENSIONS : 100(H)*110(D)*60(W)mm WEIGHTS : 740g
General Specifications
INPUT
Input range 90~132/180~264VAC (Selectable) 220~380VDC
Input frequency 47~63Hz
Inrush current (25 ํC) 25A/110VAC 55A/220VAC
OUTPUT
Hold-up time 13ms
Short protection Autorecovery
Over load protection Automatic power limited
Constant output Current control by 0~5V terminal signal (Optional)
Optional 5V/3A AUX output
for models which output voltage lower than 40VDC
Detail specifications
300 Watts
Model
LP1300D-24M
O/P Volt Adj. ± %
V : +24V ± 10%
Load (Current)1
Min.
0A
Rated
12.5A
Max.
12.5A
Ripple & Noise 4
240mV
Line REG.2
±1%
Load REG.3
±1%
Efficiency5
88% Ref.
O.V.P
31.4~34.7V
Please Choose Fit Function, And Fill in The Blank With Suitable Words.
Order Model : LP1300D-24M [] [] [] []
Optional Function :
Terminal Block : " : PCB Barrier Terminal Block
"E" : Mini Terminal Block
Monitor: " " : No Monitor
"D" : Monitor Display
Type : " " : No Display function
"A" : Output Voltage Display
Current: " " : No constant current function
"A" : Constant current by 0~5V signal
CE Standards
CE Standards
EN 55032, EN 55024, EN61000-3-3, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) LVD : EN60950-1
Safety Standards
UL 508 APPROVAL
CE Marking
Environments
Operating Temperature -15~50 ํC, Ambient
Operating Humidity 20~90% RH, No Condensing
Storage Temperature -20~85 ํC, Ambient
Vibration 2G, 10~500Hz, 3 axes
Note
1. Each output can provide up to maximum load, but total load can not exceed rated output power.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 220VAC input.
4. Ripple & Noise are measured with 20MHz oscilloscope at 220VAC by using a 20cm long 12" twisted pair-wire with a 0.1uF/630V metal capacitor & a 47uf electrolytic capacitor parallel on the test point.
5. Efficiency is measured at rated load and 220VAC input.
6. Hold-up time is measured at rated load and 220VAC input.
7. With • are CE safety approval, but no UL safety approval.
8. Output Voltage Adjustable is measured on 5% of rated load.
9. Reign Power reserve the right to change specifications at any time without notice.