ifm Safety light grids




ifm Safety light grids

  • Type 4 (IEC 61496) safety light curtains at Type 2 pricing
  • Reliable protection of hazardous areas
  • Industry standard M12 connection for simple wiring
  • Versions for the use in high pressure cleaning applications
  • Versions with active /passive system
ifm Industrial automation applications ifm High pressure cleaning applications
ifm Active/passive system
ifm Safety light grids with muting function

ifm Industrial automation applications

image Industrial automation applications
  • Type 4 (IEC 61496) safety light curtains at Type 2 pricing
  • Reliable protection of hazardous areas
  • No dead space when mounted in in L shape
  • Industry standard M12 connection for simple wiring

Applicable products: 11
 
Safety light grid OY116S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...4 m
Safety light grid OY121S
 Product
desig
nation
 Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3  810 mm 0...10 m
 Safety light grid OY952S
OY952S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid  ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 8...30 m
Safety light grid OY115S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 0...4 m
 Safety light grid OY951S
OY951S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 8...30 m
Safety light grid OY122S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...10 m
 Safety light grid OY511S
OY511S
 Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...4 m
Safety light grid OY513S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...4 m
Safety light grid OY114S
Product
desig
nation
Complies with the
requirements
Number
of beams 
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...4 m
Safety light grid OY120S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...10 m
Safety light grid OY512S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 0...4 m

Use in factory automation

OY series safety light grids are used to safeguard hazardous areas and protect personnel. Thanks to their slim design, they are suited for applications with limited mounting space. Depending on the protected area height light grids with 2, 3 or 4 light beams are available.
Safety light grids are optoelectronic safety devices consisting of one transmitter and one receiver. They conform to the safety requirements of type 2 / SIL 1 or type 4 / SIL 3.
Typical applications include access prevention or hazardous area monitoring of robot cells and production lines.


 

ifm High pressure cleaning applications

image High pressure cleaning applications
  • Integrated protective tube for IP69K rating
  • Reliable protection of hazardous areas
  • Various ranges and resolutions available
  • Resistant to steam and high-pressure cleaning
  • Hygienic and robust design

Applicable products: 3

Safety light grid OY421S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...7 m
Safety light grid OY423S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...7 m
Safety light grid OY422S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 0...7 m

Use in the food industry

OY series safety light grids for food and beverage applications can be used to safeguard hazardous areas and protect personnel. Depending on the protected area height light grids with 2, 3 or 4 light beams are available. The safety light grids with protective tube are rated IP 69K. They are resistant to high-pressure cleaning with aggressive cleaning agents.
Safety light grids are optoelectronic safety devices consisting of one transmitter and one receiver. They conform to the safety requirements of type 2 / SIL 1 or type 4 / SIL 3.
Typical applications include access prevention or hazardous area monitoring of palletizers, saws and production lines.

ifm Active/passive system

image Active/passive system
  • Transmitter and receiver in single housing for reduced wiring
  • Reliable protection of hazardous areas
  • Easy wiring and programming
  • Standardized connection via 8-pole M12 connector
Applicable products: 3

Safety light grid OY902S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 0...6 m
Safety light grid OY901S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...6 m
Safety light grid OY903S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...6 m

Active / passive system

OY series safety light grids with active / passive system are used to safeguard hazardous areas and protect personnel. The transmitter and the receiver are integrated in the housing of the active element. The passive element houses the reflecting mirrors. The electrical connection is integrated in the active element. Wiring complexity is considerably reduced.
Depending on the protected area height light grids with 2, 3 or 4 light beams are available.
Safety light grids are optoelectronic safety devices consisting of one transmitter and one receiver. They conform to the safety requirements of type 4 / SIL 3.
Typical applications include access prevention or hazardous area monitoring of robot cells and production lines.

ifm Safety light grids with muting function

image Safety light grids with muting function
  • Easy connection of the muting sensors directly to the safety light grid
  • Muting arms with pre-mounted sensors for rapid set-up
  • Parallel or crossbeam muting version for detection of variable object sizes
  • Integrated status light
  • User-friendly configuration via hardware wiring

Applicable products: 3

Safety light grid OY511S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
2 510 mm 0...4 m
Safety light grid OY513S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
4 910 mm 0...4 m
Safety light grid OY512S
Product
desig
nation
Complies with the
requirements
Number
of beams
Protected
area height
Protection area
width (low light
intensity)
Safety light grid ISO 13849-1: 2015 Category 4,
PL e; IEC 61508 SIL 3; IEC 62061 SIL 3
3 810 mm 0...4 m

Safety light grid with integrated muting function

The new generation of light grids allows for the muting mode without an external junction box or a muting relay being required as they are already integrated into the receiving element.
The supported muting versions are available as either crossbeam or parallel muting. Both versions allow transported material to be safely passed in or out, via the protected area. A status light, integrated into the receiver, allows for indication of the operating status.
The muting arms can easily be directly installed on the light grid and are available in two versions: either as muting arms with multi-beam sensors, similar to a miniature light grid,
or as pre-mounted mounting set with single-beam sensors. No complex installation and adjustments are necessary anymore.
In conclusion, a complete package for increased safety, configured for your application, quick and easy to mount.


Safety light grids

Safety light grids are used where hazardous areas must be secured. They are optoelectronic safety devices consisting of one transmitter and one receiver. They conform to the safety requirements of type 2 / SIL 1 or type 4 / SIL 3.
Typical applications include access prevention or hazardous area monitoring of robot cells and production lines. For food and beverage applications, units with protective tubes and high protection ratings are offered. Active / passive systems substantially reduce wiring complexity.

810 mm
810 mm
Visitors: 527,470