BN1024C
|
BN1524C
|
BN2024C
|
BN3024C
|
BN4048C
|
BN5048C
|
BN6048C
|
Mains model specification
|
Rated input voltage (V)
|
220/230
|
Rated output voltage range (V)
|
155~272 (±2%)
|
Rated frequency (Hz)
|
50HZ/ 60HZ (First automatic detection )
|
Frequency range (Hz)
|
47+0.3Hz ~ 55+0.3Hz for 50Hz; ( 57+0.3Hz ~ 65+0.3Hz for 60Hz)
|
Overload/short circuit protection
|
Circuit breaker
|
Efficiency
|
>95%
|
Conversion time (ms)
|
10ms (Typical values)
|
(AC transfer DC or DC to AC)
|
Current specification of bypass relay (A)
|
30
|
40
|
Specification of contravariant mode
|
Voltage output waveform
|
Sine wave
|
Rated output (VA)/(W)
|
1000/1000
|
1500/1500
|
2000/2000
|
3000/3000
|
4000/4000
|
5000/5000
|
6000/6000
|
Power factor
|
1
|
Rated output voltage (V)
|
230
|
220/230/240
|
Output voltage error range
|
±10%
|
Rated output frequency (Hz)
|
50Hz ±0.3Hz/60Hz ± 0.3Hz
|
Efficiency
|
>85%
|
Overload protection
|
(110% "load <125%) plus or minus 10%: load off after 15 minutes;
|
(125%< load <150%) plus or minus 10%: load off after 60 seconds.
|
Load >150% plus or minus 10%: power off after 20 seconds overload
|
Peak power (10 seconds) (VA)
|
3000
|
4500
|
6000
|
11000
|
12000
|
15000
|
18000
|
Motor/air conditioning capacity (piece)
|
1
|
2
|
3
|
4
|
5
|
Output short circuit protection
|
Current limit (short circuit 10 seconds after shutdown)
|
Output circuit breaker current specification (A)
|
10
|
30
|
40
|
Dc input voltage (V)
|
24/22
|
48/ 24
|
Minimum dc starting voltage (V)
|
DC input voltage range (V)
|
20.0~ 32, + 0.6Vdc deviation (low voltage alarm: 21V; Shutdown: 20V; High voltage fault: 32V; High voltage recovery: 31V)
|
40.0~ 64, + 0.6Vdc deviation (low voltage alarm: 42V; Shutdown: 40V; High voltage failure: 64V; High voltage recovery: 62V)
|
Main working mode
|
0-6 market power priority, 7-9 battery priority
|
AC input charging specifications
|
Charging current (A)
|
20
|
25
|
35
|
50
|
35
|
40
|
50
|
Charging current deviation (A)
|
± 5
|
Battery voltage range (V)
|
20 –31.4
|
40 –62.8
|
Charging short circuit protection
|
Circuit breaker
|
Charging circuit breaker specification (A)
|
10
|
30
|
The overcharge protection
|
The battery voltage is greater than 31.4 V, and the charging is closed every second and after 60 seconds
|
The battery voltage is greater than 62.8 V, and the charging is closed every second and after 60 seconds
|
Solar charging specifications
|
MPPT operating voltage range (V)
|
18-78
|
64-145
|
Maximum PV dc input voltage (V)
|
100
|
145
|
Maximum PV open circuit voltage (V)
|
78
|
145
|
Rated charging current (A)
|
45
|
60
|
Maximum load charging efficiency
|
98%
|
Battery short circuit protection
|
The fuse
|
Solar panel connection protection
|
Anti-collision protection
|
Other specifications
|
Dimensions (H x W x D mm)
|
410 x 264 x 180
|
460 x 264 x 180
|
555 x 264 x 180
|
Weight (kg)
|
16
|
19
|
22
|
26
|
31
|
34
|
36
|
To protect grade
|
IP20(Forced air cooling, fan speed adjustable )
|
Working temperature
|
-15°C to 40°C (-25ºC ~60ºC Storage temperature)
|
Working humidity
|
5% to 95%
|
Noise (dB)
|
<60
|
Communication interface
|
RS-485/ GPRS/WiFi/remote control
|
Safety Certification/EMC rating
|
CE(EN62040-1, EN62040-2)/ C2
|
Warranty (year)
|
1 year
|